Build up Infrastructure and test facilities to enable R&D in Machine drives, PQ equipments, Energy conversion systems, Electric Vehicles etc. Extend the facilities to PG and Ph.D students to enable advanced research. Extend the facilities to industries for their R&D work. Hands-on training to industries. Demonstrations / Display of R&D models developed through NaMPET funded projects.
| Green Power lab | ||
![]() |
• 25 KW Solar Power Plant • 5 KW Wind Power Plant • Simulation Lab • Test set up for conducing EMI / EMC pre-compliance tests • Environmental Test Chamber (Thermal & Humidity) |
|
| Technology Transfer Centre | ||
![]() |
• 250 kVA Test bay for testing the Proto models with maximum rating of 250 kVA • 100 kW Test bay for testing of DC units of maximum rating 100 kW • 50 kVA Test bay for testing the Proto models with maximum rating of 50 kVA • 250 kVA Auto Transformer with maximum output current of 300A • 50 kVA Auto Transformer with maximum output current of 100A. • Both 250 kVA & 50kVA transformers have following features: ~ Smooth, continuous and break-less output voltage variation ~ Remote operation possible • 100 kW DC Power source ~ DC output voltage varies from 0 to 1000V ~ Output voltage ripple less than 5% ~ Designed for continuous operation with rated current ~ Consists of 3-phase isolation transformer, Rectifier diode modules and filter chokes • Testing of battery operated Power Electronic Modules, in charging and discharging mode • 50 kVA Non-linear Load for testing Single phase and Three phase prototypes • 3 x 20 kW Linear Load for testing of Single phase and Three phase prototype Both linear and nonlinear loads have following features ~ Tripping of main contactor during fault and activation of alarm ~ Step load change with labeled illuminated push buttons ~ Emergency stop and Fan failure shutdown ~ Hand held wired operating panel for remote operation ~ Digital Metering • 2 x 4.5 kW AC/DC Programmable Load suitable for the testing of prototypes with Sine, Square and Step Wave output |
|
| Low Power lab | ||
![]() |
• Sophisticated test instruments • Simulation packages • CAD packages • Development platforms • High speed workstations • Demonstration models |
• Hi-tech soldering stations • Precision coil winding machines • Component data center • Visitors lounge • Conference Hall • DSP Workstations |
| Simulation Packages | ||
![]() |
MATLAB (Control Systems Analysis) • SimPower Systems Toolbox • MATLAB Compiler & Realtime Workshop • SIMULINK Accelerator PSIM (Power Electronics Analysis) • Basic & Motor Drive Module • Digital Control & Sim-Coupler Module |
AMESim (Multi-domain System Analysis) ModelSim (Digital Logic Analysis) |
| Development Systems | ||
![]() |
DSP • Code Composer Studio • XDS 510PP Plus • JTAG Emulator • TDS 510 USB JTAG Emulator FPGA • Quartus II • Byteblaster II Download Cable |
Microcontroller • MPLAB IDE • MPLAB C18 Compiler • MPLAB PM3 Programmer • ICE 2000 & 4000 In-Circuit Emulator |
| CAD Packages | ||
![]() |
Solid Works (Design & Drafting Package) • 3D representation of a single design component • 3D arrangement of parts and assemblies • 2D Engineering drawing of parts and assemblies • Structural Analysis |
ORCAD (PCB Design Package) • Schematics • Layout |
| Workstation | ||
![]() |
DELL Precision 670 • RAID with PERC320 Controller card • 64 MB PCIe x 16 NVIDIA |
|
| Winding Machines | ||
![]() |
Programmable Toroidal Winding Machines • Model : TCW-100B • Make : TRISHUL • Wire Gauge – 35 SWG to 25 SWG |
Programmable Coil Winding Machines • Model : Sharp Winder T-108 • Make : TRISHUL (With SMPS Winding Attachment) |
| High End Oscilloscopes | ||
![]() |
500 MHz, 5 GS/s, Non-isolated • Channel : 2 • Type : WR 6051A • Make : LeCroy Analysis Packages: • Power Measurement & Analysis • Jitter & Timing Analysis |
350 MHz, 5 GS/s, Non-isolated • Channel : 2 • Type : TDS 5034B • Make : Tektronix Analysis Packages: • Power Measurement & Analysis |
![]() |
200 MHz, 100 MS/s, Non-isolated • Channel : 4 • Type : TDS 420A • Make : Tektronix 100 MHz, 500 MS/s, Isolated • Channel : 2 • Type : THS 720P • Make : Tektronix |
Functions • Harmonics Analysis |
| Oscilloscopes | ||
![]() |
600 MHz, 5-10 GS/s,Non-isolated • Channel : 4 • Type : DSO • Make : LeCroy • Model No : WR 64Xi |
Analysis Packages • Power Measurement & Analysis • Jitter & Timing Analysis • CANbus TDM • CANbus TD |
![]() |
1 GHz • Channel : 4+16 • Type : MSO • Model : MSO4104 • Make : Tektronix |
Analysis Packages • Power Measurement & Analysis • CAN & LIN Serial Triggering & Analysis Module • RS232/422/UART Serial Triggering & Analysis Module • I2 C & SPI Serial Triggering Analysis Module |
![]() |
100 MHz, 1 GS/s,Isolated • Channel : 4 • Type : DSO • Model No : TPS 2014 • Make : Tektronix |
Functions • Harmonics Analysis • Power Waveform Analysis |
| Arbitrary Function generator | ||
![]() |
100 MHz • Channel : 2 • Type : DSO • Model No : AFG 310 • Make : Tektronix |
|
| Power Analyzer | ||
![]() |
Type : WT3000 Make : Yokogawa Bandwidth : DC, 0.1 to 1 MHz |
Functions • Frequency Measurement • Delta Calculation, LabView Driver • Harmonic Measurement • 20ch D/A Output, WT Viewer Software |
| Thermal Data Monitoring System | ||
![]() |
TCM – 24 • Type : TCM-24 • Make : Degree Controls • Sensor : Thermocouple |
• Channels : 24 • Range : -150oC to +200oC with accuracy of +1oC |
| Automatic LCR Meter | |||
![]() |
Type : PM6306/561 Make : Fluke |
||
| Electrical Loads | ||
![]() |
Non-Linear load • 30 KVA for Non-Linear load testing for UPS |
Linear Load • Linear Load 100 KW |
| DC Electronic Load | ||
![]() |
• Model No:330x, 6063B • Make: Agilent |
• Rating: 150 - 1800W, 240V, 360A • Modes of Operation: CC, CV, CR, CP Modes |
| DC Electronic Load | ||
![]() |
• Model No:63204 • Make: Chroma • Rating: 5.5 kW, 500V, 100A |
• Modes of Operation: CC, CV, CR, CP Modes • Remote Controller: A632001 |
| AC/DC Programmable Source with Analyzer | ||
![]() |
• Model: MX-30Pi-LF • Make: CaliforniaInstruments • Rating: 30 kVA AC Output: Single/3-Phase-User Selectable • HV Range: 0-300V (L-N),33.3ARMS /Ph • LV Range: 0-150V (L-N),66.6A RMS / Ph • Frequency: 16 to 500 Hz |
DC Output: • HV Range: 0-400V ,16.6A/Channel • LV Range: 0-200V ,33.3A/Channel |
![]() |
• 400 Sq.m. area for testing and development of power electronics equipments UPS, STATCOM, UPQC, HEV, AC Drives and DC Drives. |
• Loading capability of 500 KVA and dynamic loading facility upto 800 KVA. Different test bays of 50 KVA, 100 KVA, 250 KVA, 500 KVA rating are available. |
| Facilities & Equipments | ||
![]() |
Test bed and test setups for drives: • 50 HP Induction Machines coupled to separately excited DC Motor. • 22.5 KW slip recovery machine two nos. direct-coupled. |
• 10 KW test bed of Induction Motor, Induction Generator, DC Machine and SR Motor. • 10 KW eddy current loading mechanism. Incremental and Absolute Encoders for speed& position measurements. |
| PE Development Systems | ||
![]() |
• 10 KVA with 50 KVA short term rated 2-level inverter for testing control of power qualit equipments. |
• 10 KVA with 50 KVA short term rated 3-level inverter for high power STATCOM controller development. • Grid connected regenerative loading system upto 250 KVA. |
| Special Facilities | ||
![]() |
• 400V 100 AH battery bank for UPS testing and developments. • 100KVA 3-Ph Variac for varying the input supply. |
• 100 KVA Isolation Transformer |